May 26, 2022 Leave a message

Analysis and Discussion of Bucket Teeth II

Analysis and Discussion of Bucket Teeth II
Process analysis: Take two samples from the front and two samples from the back working surfaces, and grind them flat for hardness testing. It was found that there is a significant difference in hardness on the same sample, and it is preliminarily determined that the material is uneven. After grinding, polishing, and corrosion of the samples, it was found that there were obvious boundaries on each sample, but the boundary positions were different. From a macro perspective, the surrounding area appears light gray, with a darker color in the middle, indicating that the piece is likely an embedded casting. From a surface perspective, the enclosed part should also be an embedded block. Hardness tests were conducted on both sides of the boundary using HRS-150 digital Rockwell hardness tester and MHV-2000 digital microhardness tester, and significant differences were found (see Table 1). Through the above analysis, it is confirmed that the bucket teeth are of an insert structure. The enclosed part is the insert, and the surrounding part is the substrate. The composition of the two is similar, and alloying is carried out with elements such as Cr, Mn, Si, etc. The main alloying components (mass fraction,%) are 0.38C, 0.91Cr, 0.83Mn, and 0.92Si. The mechanical properties of metal materials depend on their composition and heat treatment process. The similarity in composition but differences in hardness indicate that the bucket teeth were put into use without heat treatment after casting. The subsequent organizational observations also proved this point.